BD FACSCaliburtm Item #1505
BD FACSCalibur Cytek Upgrade serial number E5615: Rebuilt 5-color flow cytometer with BD HTS, G4 computer, Cellquest software, flat screen display.
 
Workstation: Macintosh G4 with OS10, CellQuest Pro software, new 22" flat screen display and color ink-jet printer. CellQuesttm software provides high-performance acquisition and analysis tools for plotting, gating, statistical analysis, and reporting.
Lasers: 15mW 488 nm air-cooled argon, 635 nm red diode laser spatially separated for high sensitivity, minimal compensation, and maximum flexibility in fluorochrome selection.
Electronic doublet discrimination: Allows for the removal of artifacts from analysis by width and area measurements.
Fluorescence Sensitivity: <750 MESF
Coefficient of variation (CV): <3% full peak for propidium iodide–stained chicken erythrocyte nuclei.
Scatter resolution: Enables the separation of fixed platelets from noise and optimized for resolving lymphocytes, monocytes and granulocytes.
Compensation: controlled by software.
Minimum cell size: 0.2 microns.
Maximum analysis rate: 20,000 cells/sec.
Sample flow rates:12, 35 and 60 μL/min.
Power: 120 VAC +/- 10%, 50/60 Hz +/-2 Hz. Current: 15 amps maximum
Sensor module dimensions/weight: 36" w x 24" d x 26.5" h (49" high with cover open)/ 240lbs.
Manufacture date: March 2003
 

The following rebuilt option can be quoted separately:

HTS: Available without HTS.

 
Thoroughly clean, remove corrosion and re-paint all interior and exterior panels as needed . Replace filters, fluidics tubing, connectors and valves as required. Clean, inspect, or replace waste and sheath tanks. Replace BAL seal. Replace any defective optical filters for FL1-FL4. Replace any defective photomultiplier and photodiode detectors. Confirm lasers within manufacturer's specifications. Clean flow cell or replace if needed. Confirm proper operation of droplet containment module (DCM). Set sample pressure to specifications. Adjust sample flow rates for correct settings. Clean (or replace) and align optics for optimum CVs using Alignment and Calibrite beads. Print all results to be included with shipment and/or emailed to you for approval. Confirm that all workstation and instrument functions meet original factory specifications.
 
Installation by a qualified service representative quoted separately. The price will include all travel expenses and labor required to confirm proper operation at the customer's facility utilizing standard calibration procedures. Any additional time required to correct malfunctions shall be included in the quoted installation fee.
 
Instrument and/or applications training by a qualified representative are available for an additional fee. The quoted price includes travel and perdiem expenses when training is performed during an installation visit. Otherwise additional reimbursement for travel and perdiem expenses may be required.
 
Custom warranty or service contracts can be quoted separately. All components are covered unless failure is due to operator negligence. In addition, we offer unlimited telephone support for all of the products sold through Spectron Corporation regardless of warranty.
 
Shipping costs will be quoted separately. If the purchaser becomes the shipping agent for one of the products located in the State of Washington they could be subject to paying Washington State sales tax unless exempt. No such obligation exists if Spectron Corporation is the designated shipper to destinations outside the State of Washington. This equipment shall be packed in a sturdy double-walled box surrounded inside by 2" foam sheets on all sides. All components shall be individually protected within the same container. The box will be taped, strapped and attached to a pallet with additional strapping. Shipping will be arranged through a qualified airfreight carrier with full insurance.
 
Most established institutions will be approved for net-30 terms or other payment plans. Leasing or rental programs may also be available for qualified buyers with various options for an eventual purchase. Washington State customers or others arranging shipment or picking up products themselves may be subject to Washington State sales tax unless exempt. Spectron Corporation will inform prospective buyers of any such circumstance that could result in a tax liability. Otherwise, buyers would only be subject to applicable use taxes that they might be required to pay directly to their respective state.
 
Spectron Corporation would appreciate the opportunity to bid on a service contract covering our products as well as other flow cytometers located at your facility. Please inquire into any modifications to the listed products that would better suit your requirements. We strive for complete satisfaction.
 